Assembly manual for HPE fittings (D20-110)
ASSEMBLY MANUAL
For HPE fittings from 20 to 110 mm diameter with PN 10 and PN16
|
|
|
|
|
|
|
|
|
IMPORTANT:
- The end of the pipe has to be rounded and cleaned from chip
- From 20 to 32 mm diameter it is enough if the nut is pulled by hand
- Above 40 mm diameter some kind of wrench or tool has to be used in order to reach the perfect bonding. (At D40 - 25 Nm, D50 - 30 Nm, D63 - 35 Nm, D75 - 40 Nm, D90-110 - 50 Nm torque has to be used to pull the cap)
- If the nut is not fixed completely, there can be dripping or flowing at the spacer or the pressure can fire the pipe from the fitting
- The threaded end of the HPE fitting has to be coiled with PTFE (polytetrafluoroethylene) tape or braid
- The threaded end of HPE fitting has to be coiled in completely (useful thread lenght)